• About
    • Login
    View Item 
    •   Institutional Repository Home
    • Vanderbilt University Medical Center
    • Cardiovascular Medicine
    • Research reports
    • View Item
    •   Institutional Repository Home
    • Vanderbilt University Medical Center
    • Cardiovascular Medicine
    • Research reports
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Browse

    All of Institutional RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsDepartmentThis CollectionBy Issue DateAuthorsTitlesSubjectsDepartment

    My Account

    LoginRegister

    Echocardiographic Detection of Occult Diastolic Dysfunction in Pulmonary Hypertension After Fluid Challenge

    Agrawal, Vineet
    (D'Alto, Michele
    Naeije, Robert
    Romeo, Emanuele
    Xu, Meng
    Assad, Tufik R.
    Robbins, Ivan M.
    Newman, John H.
    Pugh, Meredith E.
    Hemnes, Anna R.
    Brittain, Evan L.
    : http://hdl.handle.net/1803/10265
    : 2019-09-23

    Abstract

    Background-Identification of occult diastolic dysfunction often requires invasive right heart catheterization with provocative maneuvers such as fluid challenge. Non-invasive predictors of occult diastolic dysfunction have not been identified. We hypothesized that echocardiographic measures of diastolic function are associated with occult diastolic dysfunction identified at catheterization. Methods and Results-We retrospectively examined hemodynamic and echocardiographic data from consecutive patients referred for right heart catheterization with fluid challenge from 2009 to 2017. A replication cohort of 52 patients who prospectively underwent simultaneous echocardiography and right heart catheterization before and after fluid challenge at Monaldi Hospital, Naples, Italy. In the retrospective cohort of 126 patients (83% female, 56+14 years), 27/126 (21%) had occult diastolic dysfunction. After adjusting for tricuspid regurgitant velocity and left atrial volume index, E velocity (odds ratio 1.8, 95% CI 1.1-2.9, P 0.01) and E/e' (odds ratio 1.9, 95% CI 1.1-3, P 0.005) were associated with occult diastolic dysfunction with an optimal threshold of E/e' >8.6 for occult diastolic dysfunction (sensitivity 70%, specificity 64%). In the prospective cohort, 5/52 (10%) patients had diastolic dysfunction after fluid challenge. Resting E/e' (odds ratio 8.75, 95% CI 2.3-33, P=0.001) and E velocity (odds ratio 7.7, 95% CI 2-29, P=0.003) remained associated with occult diastolic dysfunction with optimal threshold of E/e' >8 (sensitivity 73%, specificity 90%). Conclusions-Among patients referred for right heart catheterization with fluid challenge, E velocity and E/e' are associated with occult diastolic dysfunction after fluid challenge. These findings suggest that routine echocardiographic measurements may help identify patients like to have occult diastolic dysfunction non-invasively.
    Show full item record

    Files in this item

    Thumbnail
    Name:
    Echocardiographic Detection of ...
    Size:
    1.605Mb
    Format:
    PDF
    View/Open

    This item appears in the following collection(s):

    • Research reports

    Connect with Vanderbilt Libraries

    Your Vanderbilt

    • Alumni
    • Current Students
    • Faculty & Staff
    • International Students
    • Media
    • Parents & Family
    • Prospective Students
    • Researchers
    • Sports Fans
    • Visitors & Neighbors

    Support the Jean and Alexander Heard Libraries

    Support the Library...Give Now

    Gifts to the Libraries support the learning and research needs of the entire Vanderbilt community. Learn more about giving to the Libraries.

    Become a Friend of the Libraries

    Quick Links

    • Hours
    • About
    • Employment
    • Staff Directory
    • Accessibility Services
    • Contact
    • Vanderbilt Home
    • Privacy Policy