Theory and Implementation of L-DNA Hybridization Sensors for PCR Cycle Control and Real-Time Target Characterization
Date
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
Molecular diagnostics are among our most powerful tools for addressing infectious disease, from informing treatment to containing outbreaks. In low-resource environments and times of duress such as epidemics, healthcare infrastructure is often insufficient to adequately test all patients. Supply chain issues, staffing shortages, and transport delays to central laboratories contribute to long testing turnarounds, by which time the infected patient could worsen or infect others. A “point-of-care” approach is thus more desirable, wherein all diagnostic steps are performed close to the patient and without relying on external laboratories or supplies. Unfortunately, many gold standard laboratory diagnostics—like polymerase chain reaction—are too environmentally sensitive, slow, and labor-intensive to take to the point-of-care, while many point-of-care tests lack equivalent sensitivity and specificity. As a solution, the work presented in this dissertation focuses on “adaptive PCR”—an alternative PCR control methodology that uses hybridization of stereoisomeric L-DNA to make cycling decisions instead of using temperatures—to create a single-sample PCR system that reduces false negatives, reduces time to result, and enables new post-PCR analyses. New, hybridization theory-based guidelines were created for the L-DNA control strands and applied to the background-sensitive SARS-CoV-2 N2 reaction in unextracted nasopharyngeal samples, preventing false negatives. Time to result was reduced by 1370 nm photothermal heating from an hour-long assay time to a point-of-care compliant 15 minutes without sensitivity loss. Finally, two new post-PCR analysis steps, melt analysis and amplicon quantification, were developed. The melt temperatures of the L-DNA control strands were used as endpoints to measure the melt temperature of a PCR product with low variance across samples. Simultaneously, the height of the L-DNA melt peak was used to calculate the relationship of amplicon concentration to fluorescence, which enabled target quantification. Estimates were accurate for all starting concentrations but the lowest, suggesting that this technique is a potential framework for single-sample absolute quantification. This work represents a significant step toward a PCR system capable of reducing sample preparation and assay time, and further establishes new, broadly applicable techniques for single-sample PCR analysis.