Learning-Based Active Perception for Autonomous Viewpoint Control in Image-Guided Breast Conserving Surgery

Loading...
Thumbnail Image

Journal Title

Journal ISSN

Volume Title

Publisher

Abstract

Image-guided breast-conserving surgery relies on consistent visibility of surgical regions of interest to ensure complete tumor excision while preserving healthy tissue. Current surgical imaging systems use static camera configurations that cannot adapt to intraoperative conditions such as tool occlusions, surgical table adjustments, or surgeon repositioning. This limits visualization quality and increases reliance on manual camera adjustments, disrupting surgical workflow. We present an autonomous robotic active perception system that learns optimal camera viewpoint selection through machine learning and executes viewpoint changes autonomously to maintain continuous, high-quality visualization throughout surgery. Our system integrates a KUKA LBR Med 14 collaborative robot equipped with a ZED 2i stereo camera and NDI Polaris Lyra optical tracker. The approach combines deep learning-based fiducial detection, learned viewpoint quality prediction via neural networks, continuous pose optimization using differential evolution, and safe motion planning. A composite quality metric balances four competing objectives: fiducial visibility, reference point visibility, optimal camera-to-target distance, and surface normal alignment. To train the quality prediction model, we collected 240 viewpoint samples, systematically varying camera position and orientation while measuring ground-truth quality metrics. The trained neural network achieved mean absolute error of 0.070 for fiducial visibility (FVS) prediction, where FVS ranges from 0 (no fiducials visible) to 1.0 (all fiducials visible) with 75% of predictions within acceptable tolerance (0.10 error). Camera distance and surface alignment predictions demonstrated strong performance, enabling effective geometric reasoning for viewpoint optimization. Validation on novel trajectory data showed a good correlation between predicted and actual quality, confirming generalization beyond the training distribution. The motion planning pipeline achieved smooth, collision-free trajectories averaging 3.2 seconds planning time and 102 Hz control frequency. This work demonstrates the feasibility of learning-based active perception for surgical robotics, establishing a foundation for intelligent surgical camera systems that can autonomously maintain optimal visualization.

Description

Keywords

image-guided surgery, surgical robotics, active perception, viewpoint optimization, neural networks, motion planning

Citation

Endorsement

Review

Supplemented By

Referenced By