STORK: Development of an EMR-Embedded, Human-Centered Shift Handoff Innovation for Neonatal Advanced Practice Providers
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
Purpose: Shift handoff communication is a critical safety process in neonatal intensive care units (NICUs), yet handoffs among Advanced Practice Providers (APPs) may vary widely in structure, duration, and content. Variability in handoff communication increases the risk of omissions, inefficiencies, and unclear task ownership. Evidence from pediatric settings demonstrates that structured handoff frameworks can improve communication reliability and reduce errors. The purpose of this innovation project was to design a standardized, electronic medical record (EMR)-embedded shift handoff tool for neonatal APPs informed by stakeholder input and evidence-based handoff frameworks.
Methods: This innovation project was conducted in a Level IV NICU at the University of Michigan C.S. Mott Children’s Hospital. A pre-implementation survey was distributed to all neonatal APPs to evaluate current handoff practices, perceived barriers, and desired features of a standardized tool. Twenty-five of thirty-eight eligible providers responded (65.7%). Survey findings informed the development of the STORK framework, a structured handoff protocol consisting of five domains: Snapshot, Today’s Changes, Overview/Systems, Responsibilities, and Key Contingencies. The tool was designed for integration within the Epic EMR and accompanied by an implementation strategy that included education materials, micro-training, and a super-user support model. Planned evaluation measures included compliance, handoff time per patient, and interruptions during handoff.
Results: Survey findings demonstrated strong support for a standardized, EMR-embedded handoff tool. Most respondents preferred a systems-based handoff structure (71%) and an Epic-integrated template (96%). Desired features included auto-pull of key clinical data (75%), a clear action or to-do list (83%), contingency planning (63%), and a “Today’s Changes” section (46%). Anticipated barriers included cultural resistance to workflow change (75%), interruptions during handoff (58%), concerns regarding accuracy of auto-pulled data (46%), and time constraints (42%). Although Epic integration delays prevented implementation during this project period, the STORK framework, education materials, EMR specifications, and evaluation plan were completed, positioning the unit for rapid implementation and iterative Plan-Do-Study-Act testing.
Implications for practice: The STORK framework offers a structured approach to neonatal APP handoff communication that aligns local workflow needs with evidence-based handoff practices. Standardizing handoff communication may improve efficiency, clarify task ownership, and reduce variability in patient sign-out. Embedding the tool within the EMR supports consistent documentation and facilitates access to key clinical information. With implementation supported by brief education and peer champions, STORK has the potential to strengthen communication reliability and promote safer patient care transitions in the NICU.