Stroke is one of the major causes of loss if dexterity in human hand, preventing effective self-care and employment opportunities among the patients. In this thesis, an exoskeleton device for thumb rehabilitation is discussed. Subsequently, a mathematical framework for modeling the exoskeleton is developed. A kinematic analysis for the coupled motion of the thumb-exoskeleton system is presented. Later on, in the thesis a closed-loop inverse kinematics scheme is implemented. The thumb-exoskeleton is a redundant system. The redundancy is resolved at the velocity and acceleration levels to limit the motion of the thumb within the natural range of motion of the thumb.

Description

Keywords

Thumb exoskeleton, Kinematic Analysis, Kinematics, Thumb Rehabilitation, Thumb-exoskeleton